Operation Of The Modular KIT 170 GHz – 2 MW Longer-PulseCoaxial-Cavity Gyrotron With Pulses Up To 50ms
Paper (FACIL 1)Fri, 13 Nov 2020 03:45pm to 04:00pm
Room: Tesla
The KIT 170 GHz – 2 MW longer-pulse coaxial-cavity gyrotron is continuously upgraded with the goal to reach 1 s with a modular construction. In this work, we present the latest experimental results that were achieved after modifications on the mirror-box, the collector and the cooling system of the gyrotron. In particular, it was possible to demonstrate pulses with output power up to 2 MW and pulse length up to 50 ms.
Download Abstract: pid6388143.pdf
Presenter: Anonymous
Authors: Ioannidis, Zisis; Rzesnicki, Tomasz; Avramidis, Konstantinos; Gantebein, Gerd; Illy, Stefan; Jin, Jianbo; Krier, Laurent; Pagonakis, Ioannis; Ruess, Sebastian; Schmid, Martin; Thumm, Manfred; Jelonnek, John
Karlsruhe Institute of Technology